Solar Reflective & Heat Control Coatings

DY-36

Rare-Earth Transparent Thermal Insulation Coating

Transparent thermal insulation coating for clean glazing and windows where solar heat control and visible transparency are both required.

DY-36 transparent thermal insulation coating package

Transparent Thermal Insulation Coating for Glass

DY-36 is a rare-earth transparent thermal insulation coating for existing glazing and windows where solar heat control and visible transparency are both required. Unlike an opaque solar reflective roof coating, this glass heat insulation coating is applied as a transparent film to a clean glass surface. Selection should review the glazing type, existing films or treatments, required appearance, indoor application conditions and the verified optical data in the product information. Application quality depends on thorough cleaning, residue removal, uniform material preparation and continuous placement without trapped air. A representative trial area is appropriate where visual appearance, compatibility or working technique needs to be confirmed before broader application.

A transparent coating based on an inorganic-organic interpenetrating polymer network with rare-earth oxides and nano-scale ATO/ITO functional fillers.

Solar reflectionOutdoor protectionThermal control

Problems addressed

Solar heat through glazingUV and infrared transmissionExisting glass requiring an applied coating

Infrared Blocking and Transparency

When this product direction fits

Transparent heat-control coating for existing glass, windows and glazing surfaces.

How this system differs

DY-36 has a transparent heat-control role for existing glass, windows and glazing. Review that documented glass-surface scope rather than applying the family's opaque roof or storage-tank surface context to this product.

What must be confirmed

Suitability depends on the actual substrate, medium, concentration, temperature cycle, exposure mode and application window. Final system selection and project-specific instructions require technical review.

Transparent Glass Coating or Solar Reflective Coating?

DY-36 is transparent and intended for compatible glazing. DY-21 is an opaque solar reflective coating for roofs, tanks and exposed steel. The substrate and required appearance separate the two applications.

Product features and advantages

Visible light transmittance ≥70%

Infrared shielding ≥80%

UV shielding >90%

Can be applied to existing glass

Typical application context

Window and Glazing Solar Heat Control

Industrial Buildings & Logistics · Building Energy Efficiency: application review for Glazing · Windows · Transparent building envelope.

Solar-reflective systems for roofs, tanks and exposed surfaces where absorbed solar heat is the main concern. Confirm the substrate, exposure and maintenance access before final selection.

Suitable equipment

GlazingWindowsTransparent building envelope

Industries

Industrial Buildings & Logistics

Building Energy Efficiency

Substrates and areas

Clean glass surfaces

Operating conditions

Indoor application at 5-35°C · Relative humidity <70%

DY-36

Technical parameters

Only values available in the reviewed product source are shown.

Technical parametersValueSource
AppearanceTransparent film
Application Environment5-35°C; relative humidity <70%Product source
Application Rate20 cc/m²Product source
Touch Dry Time30 min (2-3 h condition stated in source)Product source
Hard Cure Time24 h (4-5 h condition stated in source)Product source
Deodorisation Time30 dProduct source
Visible Light Transmittance≥70%Product source
Infrared Shielding≥80%Product source
UV Shielding>90%Product source

Application Conditions

01

Confirm substrate condition, contamination, corrosion, defects and access before work starts.

02

Remove oil, dust and loose material; prepare cleanliness and profile to the reviewed product procedure.

03

Check compatibility of retained coatings and complete a representative trial area when the existing system is uncertain.

04

Prepare and mix only according to the product source; do not improvise ratio, thinner or pot life.

05

Build a continuous system in controlled layers, with special attention to edges, welds, joints and shadow zones.

06

Protect the applied area through curing, then inspect continuity, visible defects and recorded source-backed acceptance items.

Source-specific procedure

01

Surface Preparation

Clean the glass twice, remove detergent residue, then wipe with ethanol and allow it to evaporate.

02

Application Environment

5-35°C; relative humidity <70%.

03

Mixing

Stir for at least 30 seconds and apply immediately.

04

Application Tools

Special sponge fitted to an aluminium channel.

05

Curing

Touch dry 30 minutes; hardening 24 hours.

06

Precautions

Apply continuously and avoid trapped air in the applicator sponge.

Packaging, storage and transport

StorageWater-based product; store sealed and request batch-specific handling guidance before use

Official product source: Rare-earth transparent heat insulation coating / DY-36 PDF

Quality checks

Check surface-preparation records, environmental conditions, layer continuity, edges, welds and visible defects. Use only acceptance criteria stated in the reviewed product or project documents.

Maintenance and repair

Inspect representative high-risk locations during planned maintenance. Clean the area, identify the cause of damage, feather sound edges and verify compatibility before local repair.

Scope and limitations

Suitability depends on the actual substrate, medium, concentration, temperature cycle, exposure mode and application window. Final system selection and project-specific instructions require technical review.

Technical documents

Documents for project evaluation

TDS, SDS, MSDS, test reports and other project-related technical documents are available based on specific project requirements. Please contact us through WhatsApp.

Request via WhatsApp

Frequently Asked Questions

What is transparent thermal insulation coating?

It is a transparent applied film intended to manage parts of solar transmission through compatible glazing while retaining the verified level of visible-light transmission.

Can thermal-control coating be applied to glass?

DY-36 is intended for clean compatible glass surfaces. Glazing type, existing treatments, appearance and application conditions should be checked first.

What should be reviewed before coating windows or glazing?

Review glass type, existing film or coating, cleanliness, required transparency, indoor temperature and humidity, access and the ability to apply a continuous film.

Related solutions

Industries

Related technical content

Related cases

Petrochemical Storage Tank Exterior Protection, industrial site image
PetrochemicalVertical storage tank

Petrochemical Storage Tank Exterior Protection

Outdoor solar exposure, industrial atmosphere and chloride-bearing coastal conditions.

View case
Storage Tank Solar-Reflective Application, industrial site image
PetrochemicalLarge storage tank roof and exterior

Storage Tank Solar-Reflective Application

Strong solar radiation and outdoor weather exposure on roofs, tanks and building surfaces.

View case
Steel-Structure Factory Roof Solar-Reflective Application, industrial site image
Buildings & Energy EfficiencyMetal factory roof

Steel-Structure Factory Roof Solar-Reflective Application

Large exposed roof areas, joints and weathered substrates receive sustained solar radiation.

View case
Large Arched Industrial Roof Reflective Coating, industrial site image
Buildings & Energy EfficiencyLarge arched metal roof

Large Arched Industrial Roof Reflective Coating

Large exposed roof areas, joints and weathered substrates receive sustained solar radiation.

View case

Related products

DY-21 DAYU-X
DY-21

Water-Based Solar Reflective Coating

Solar-reflective systems for roofs, tanks and exposed surfaces where absorbed solar heat is the main concern.

Solar reflectionOutdoor protectionThermal control

Typical equipmentIndustrial roof · Storage tank

View product
DY-27 DAYU-X
DY-27

Building Wall Thermal Insulation Coating

Thermal-management materials for equipment, pipework and building assemblies where heat-transfer control is required.

Thermal insulationHeat-loss controlComplex geometry

Typical equipmentBuilding wall · Industrial building envelope

View product
DY-88 DAYU-X
DY-88

Aerogel Thermal Insulation Blanket

Flexible aerogel insulation blanket for equipment, pipework and tank insulation assemblies.

Thermal insulationHeat-loss controlComplex geometry

Typical equipmentIndustrial pipeline · Process equipment

View product
DY-22 DAYU-X
DY-22

Thermal Insulation Energy-Saving Coating

Thermal-management materials for equipment, pipework and building assemblies where heat-transfer control is required.

Thermal insulationHeat-loss controlComplex geometry

Typical equipmentStorage tank · Pipeline

View product

DAYU-X

Need Technical Support?

Share the equipment, substrate, medium, temperature and current problem for a focused technical review.

Contact Us